摘要(Abstract):
实际运行状态的干式空心电抗器在故障诊断时,减少故障误报率和漏报率是其研究的重点和难点。对此,提出基于加权朴素贝叶斯的干式空心电抗器状态评估方法。首先建立基于多物理场耦合的电抗器匝间短路故障仿真模型,并通过搭建电抗器运行试验平台验证了仿真方法的有效性;然后仿真和分析了多运行状态下电抗器电流幅值、电流谐波、阻抗角和热点温度等特征量变化规律,获取电抗器正常和已知故障样本集;最后提出基于多状态特征量的加权朴素贝叶斯电抗器状态评估方法。算例结果表明:该方法具有分类准确率高、训练样本少等优点,是电抗器运行状态识别和分类的有效方法。
关键词(KeyWords): 干式空心电抗器;等效模型;加权朴素贝叶斯;状态评估
基金项目(Foundation): 国家电网公司总部科技项目(5500-202119131A-0-0-00)~~
作者(Author): 赵启承,张波,洪金琪,韩国文,韩文芳,陈锋
DOI: 10.19666/j.rlfd.202306040
参考文献(References):
- [1]吴冬文. 35 kV干式电抗器温度场分布及红外测温方法研究[J].变压器, 2013, 50(9):62-65.WU Dongwen. Temperature field distribution and infrared temperature measurement method research of 35 kV drytype reactor[J]. Transformer, 2013, 50(9):62-65.
- [2]裴运军,林良顺,胡泰.一种改良型干式空心电抗器的无线测温装置设计[J].电网与清洁能源, 2016,32(10):79-82.PEI Yunjun, LIN Liangshun, HU Tai. Design of wireless temperature measurement device based on an improved dry type air core reactor[J]. Advances of Power System&Hydroelectric Engineering, 2016, 32(10):79-82.
- [3]陈嵘,杨松伟,程泳,等.干式空心并联电抗器电磁-流体-温度场耦合计算与分析[J].高电压技术, 2017,43(9):3021-3028.CHEN Rong, YANG Songwei, CHENG Yong, et al.Electromagnetic-fluid-temperature coupling calculation and analysis of dry-typeair-core shunt reactor[J]. High Voltage Engineering, 2017, 43(9):3021-3028.
- [4]王梓,刘溟,邹建明,等.基于TVOC检测的干式空心电抗器过热故障诊断方法[J].高电压技术, 2017,43(11):3756-3762.WANG Zi, LIU Ming, ZOU Jianming, et al. Diagnostic method of dry-type air-core reactors overheating fault based on monitoring TVOC[J]. High Voltage Engineering,2017, 43(11):3756-3762.
- [5]孙才新,陈伟根,李俭,等.电器设备油中气体在线监测与故障诊断技术[M].北京:科学出版社, 2003:1.SUN Caixin, CHEN Weigen, LI Jian, et al. Online monitoring and fault diagnosis technology of gas in oil of electrical equipment[M]. Beijing:Science Press. 2003:1.
- [6]古亮,刘肖光,陈新岗,等.干式空心电抗器匝间短路汇流母排电流变化规律的研究[J].高压电器, 2018,54(10):145-150.GU Liang, LIU Xiaoguang, CHEN Xingang, et al.Research on current imbalance law of bus-barcaused by inter-turnshort circuit of dry-typeair-corereactor[J]. High Voltage Apparatus, 2018, 54(10):145-150.
- [7]黄新波,周岩,朱永灿,等.干式空心电抗器匝间短路故障在线监测技术[J].电力系统自动化, 2019, 43(2):150-155.HUANG Xinbo, ZHOU Yan, ZHU Yongcan, et al. Online monitoring technology of inter-turn short circuit fault of dry-type air-core reactor[J]. Power System Automation,2019, 43(2):150-155.
- [8]郭哲,郭志广,贾跟卯,等.空心并联电抗器匝间故障三阶段特性分析及综合保护方法[J].电力系统自动化,2020, 44(8):149-156.GUO Zhe, GUO Zhiguang, JIA Genmao, et al. Threestage characteristic analysis on inter-turn fault and comprehensive protection method for air-core shunt reactor[J]. Automation of Electric Power Systems, 2020,44(8):149-156.
- [9]张波,王坚俊,韩文芳,等.干式空心电抗器匝间电弧性短路故障特征提取及诊断方法研究[J].热力发电,2021, 50(12):145-152.ZHANG Bo, WANG Jianjun, HAN Wenfang, et al. Study on feature extraction and diagnosis method of inter-turn arc short circuit fault in dry-type air core reactor[J].Thermal Power Generation, 2021, 50(12):145-152.
- [10]赵春明,敖明,王永红,等.基于功率因数变化量的干式空心电抗器匝间短路故障在线监测方法[J].电力电容器与无功补偿, 2020, 41(3):87-93.ZHAO Chunming, AO Ming, WANG Yonghong, et al.Online monitoring method of inter-turn short circuit fault of dry-type air-core reactor based on power factor variation[J]. Power Capacitor and Reactive Power Compensation, 2020, 41(3):87-93.
- [11]江秀臣,盛戈皞.电力设备状态大数据分析的研究和应用[J].高电压技术, 2018, 44(4):1041-1050.JIANG Xiuchen, SHENG Gehao. Research and application of big data analysis of power equipment condition[J].High Voltage Engineering, 2018, 44(4):1041-1050.
- [12]蒲天骄,乔骥,韩笑,等.人工智能技术在电力设备运维检修中的研究及应用[J].高电压技术, 2020, 46(2):369-383.PU Tianjiao, QIAO Ji, HAN Xiao, et al. Research and application of artificial intelligence in operation and maintenance for power equipment[J]. High Voltage Engineering, 2020, 46(2):369-383.
- [13]廖瑞金,王有元,刘航,等.输变电设备状态评估方法的研究现状[J].高电压技术, 2018, 44(11):3454-3464.LIAO Ruijin, WANG Youyuan, LIU Hang, et al. Research status of condition assessment method for power equipment[J]. High Voltage Engineering, 2018, 44(11):3454-3464.
- [14]李刚,张博,赵文清,等.电力设备状态评估中的数据科学问题:挑战与展望[J].电力系统自动化, 2018,42(21):10-20.LI Gang, ZHANG Bo, ZHAO Wenqing, et al. Data science issues in state evaluation of power equipment:challenges and prospects[J]. Automation of Electric Power Systems, 2018, 42(21):10-20.
- [15]唐文虎,牛哲文,赵柏宁,等.数据驱动的人工智能技术在电力设备状态分析中的研究与应用[J].高电压技术, 2020, 46(9):2985-2999.TANG Wenhu, NIU Zhewen, ZHAO Boning, et al.Research and application of data-driven artificial intelligence technology for condition analysis of power equipment[J]. High Voltage Engineering, 2020, 46(9):2985-2999.
- [16]耿苏杰,王秀利.基于模糊贝叶斯网络的电力设备故障诊断和状态评估[J].计算机集成制造系统, 2021,27(1):63-71.GENG Sujie, WANG Xiuli. Fault diagnosis and state estimation of power equipment based on fuzzy Bayesian network[J]. Computer Integrated Manufacturing System,2021, 27(1):63-71.
- [17]魏波涛.基于贝叶斯深度学习的高维小样本数据分类研究[D].北京:华北电力大学, 2020:1.WEI Botao. Research on classification of high-dimensional small sample data based on Bayes deep learning[D]. North China Electric Power University, 2020:1.
- [18]赵文清,朱永利,姜波,等.基于贝叶斯网络的电力变压器状态评估[J].高电压技术, 2008, 34(5):1032-1039.ZHAO Wenqing, ZHU Yongli, JIANG Bo, et al. Condition assessment for power transformers by Bayes networks[J].High Voltage Technology, 2008, 34(5):1032-1038.
- [19]姜志鹏.干式空心电抗器多物理场分析及应用研究[D].武汉:武汉大学, 2014:1.JIANG Zhipeng. Multi-physics analysis and application research of dry-type air-core reactor[D]. Wuhan:Wuhan University, 2014:1.
- [20]范茜勉.电抗器匝间短路的影响及检测方法[D].郑州:华北水利水电大学, 2016:1.FAN Qianmian. The influence of reactor turn-to-turn short circuit and its detection method[D]. Zhengzhou:North China University of Water Resources and Electric Power,2016:1.
- [21]叶占刚.干式空心电抗器的结构特点及其使用寿命的分析[J].变压器, 1995(8):23-25.YE Zhangang. Analysis of structural characteristics and service life of dry-type air core reactor[J]. Transformer,1995(8):23-25.